Views: 0 Author: Site Editor Publish Time: 2022-03-02 Origin: Site
1. When installing couplings, pulleys, sprockets and other connecting parts on the output shaft of the cycloid reducer, the direct hammering method is not allowed, because the output shaft structure of the reducer cannot withstand the axial hammering force , can be screwed into the shaft end screw into the coupling.
2. The shaft diameters of the output shaft and input shaft should be matched with GB1568-79.
3. The lifting ring screws on the reducer are only used for lifting the reducer.
4. When installing the reducer on the foundation, the elevation of the installation center line of the reducer, the levelness and the related dimensions of the connected parts should be calibrated. The concentricity of the alignment shaft should not exceed the range allowed by the coupling.
5. When calibrating the reducer, it can be done with steel pads or cast iron pads. The height of the pads does not exceed three, and it can also be done with wedge iron, but after the reducer is calibrated, it should be replaced with a flat pad.
6. The configuration of the pads should avoid causing the deformation of the body, and should be arranged symmetrically on both sides of the foundation bolts, and the distance from each other can be enough to allow the water slurry to circulate freely during irrigation.
7. The irrigation of cement slurry should be dense, and there should be no air bubbles, voids and other defects.